EVCO EVB1256N9D User Manual
Page 57

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 57 of 92
F3
0
15
min
0
0
0
0
0
0
0
0
maximum duration of evaporator fan deactivation; see
also
F7
(during
evaporator
fan
deactivation
the
compressor can be switched on, the defrosting output will
remain deactivated and the evaporator fan will remain
switched off)
F4
0
240
s
60
60
60
60
60
60
60
60
duration of evaporator fan deactivation during operation
in low relative humidity conditions with the compressor
switched off; see also F5 (only if F0 = 5)
F5
0
240
s
10
10
10
10
10
10
10
10
duration of evaporator fan activation during operation in
low relative humidity conditions with the compressor
switched off; see also F4 (only if F0 = 5)
F6
0
1
- - - -
0
0
0
0
0
0
0
0
operation in low or high relative humidity conditions (only
if F0 = 5) (28)
0
=
low relative humidity (during operation in low
relative humidity conditions the evaporator fan
shall function in parallel with the compressor; see
also F4 and F5)
1
=
high relative humidity (during operation in high
relative humidity conditions the evaporator fan
shall be switched on)
F7
-99.0
99.0
°C/°F
(1)
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
evaporator temperature below which the evaporator fan is
restarted (in respect to the working set point, that is to
say “working set-point + F7”); see also F3