EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 57 of 92

F3

0

15

min

0

0

0

0

0

0

0

0

maximum duration of evaporator fan deactivation; see

also

F7

(during

evaporator

fan

deactivation

the

compressor can be switched on, the defrosting output will

remain deactivated and the evaporator fan will remain

switched off)

F4

0

240

s

60

60

60

60

60

60

60

60

duration of evaporator fan deactivation during operation

in low relative humidity conditions with the compressor

switched off; see also F5 (only if F0 = 5)

F5

0

240

s

10

10

10

10

10

10

10

10

duration of evaporator fan activation during operation in

low relative humidity conditions with the compressor

switched off; see also F4 (only if F0 = 5)

F6

0

1

- - - -

0

0

0

0

0

0

0

0

operation in low or high relative humidity conditions (only

if F0 = 5) (28)

0

=

low relative humidity (during operation in low

relative humidity conditions the evaporator fan

shall function in parallel with the compressor; see

also F4 and F5)

1

=

high relative humidity (during operation in high

relative humidity conditions the evaporator fan

shall be switched on)

F7

-99.0

99.0

°C/°F

(1)

5.0

5.0

5.0

5.0

5.0

5.0

5.0

5.0

evaporator temperature below which the evaporator fan is

restarted (in respect to the working set point, that is to

say “working set-point + F7”); see also F3