5 list of configuration parameters – EVCO EVB1256N9D User Manual
Page 40

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 40 of 92
12.5
List of configuration parameters
The following table shows the meaning of the configuration parameters of the devices.
PARAM.
MIN.
MAX.
M.U.
E
V
B
1
2
0
4
E
V
B
1
2
1
4
E
V
B
1
2
0
6
E
V
B
1
2
1
6
E
V
B
1
2
2
6
E
V
B
1
2
3
6
E
V
B
1
2
4
6
E
V
B
1
2
5
6
WORKING SETPOINT
SP
r1
r2
°C/°F (1)
-18.0
-18.0
-18.0
-18.0
-18.0
-18.0
-18.0
-18.0
Working set-point; see also r0
PARAM.
MIN.
MAX.
M.U.
E
V
B
1
2
0
4
E
V
B
1
2
1
4
E
V
B
1
2
0
6
E
V
B
1
2
1
6
E
V
B
1
2
2
6
E
V
B
1
2
3
6
E
V
B
1
2
4
6
E
V
B
1
2
5
6
MEASUREMENT INPUTS
CA1
-25.0
25.0
°C/°F (1)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
if P4 = 0, 1, 2 o 3, room temperature offset
if P4 = 4, inlet air temperature offset
CA2
-25.0
25.0
°C/°F (1)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
evaporator temperature offset
CA3
-25.0
25.0
°C/°F (1)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
auxiliary temperature offset (see P4)
CA4
-25.0
25.0
°C/°F (1)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0.0
0.0
evaporation temperature offset
CA5
-25.0
25.0
points/10
(4)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0
0
vapour pressure offset
P0
0
2
- - - -
1
1
1
1
1
1
1
1
temperature probe type
0
=
PTC
1
=
NTC
2
= Pt 1000