P1

0

1

- - - -

1

1

1

1

1

1

1

1

degree Celsius decimal point

1

=

YES

P2

0

1

- - - -

0

0

0

0

0

0

0

0

temperature unit of measurement (2)

0

=

degree Celsius

1

=

degree Fahrenheit

P3

0

2

- - - -

1

1

1

1

1

1

1

1

evaporator temperature probe function

0

=

probe absent

1

=

defrosting probe and probe for evaporator fan

thermostating

2

=

probe for evaporator fan thermostating

P4

0

4

- - - -

3

3

3

3

3

3

3

3

magnitude recorded by the auxiliary temperature probe

0

=

probe absent

1

=

condenser temperature

2

=

critical temperature

3

=

evaporator 2 temperature

4

=

outlet

air

temperature;

in

this

case

the

temperature associated with the setting shall be

the CPT (Calculated Product Temperature) one;

see also P7

P5

0

4

- - - -

0

0

0

0

0

0

0

0

magnitude displayed during normal operation

0

=

if P4 = 0, 1, 2 or 3, room temperature

if P4 = 4, CPT temperature

1

=

working set-point

2

=

evaporator temperature

3

=

temperature recorded by the auxiliary probe (see

P4)

4

=

inlet air temperature (only if P4 = 4 )