EVCO EVB1256N9D User Manual
Page 44

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 44 of 92
h06
0
999
s
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
30
30
PID action derivative time
h07
1
250
s
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
5
5
starting delay
h08
-1
100
%
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
-1
-1
percentage valve open during the manual operation
-1 = the superheating will be enabled
h09
0
100
%
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0
0
percentage valve open during the hot gas defrost (during
the pre-dripping and the dripping the valve will be closed,
during the evaporator fan delay the valve opening will be
function of the algorithm of regulation)
h10
0
45.0
bar g /
PSI g (4)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
1.0
1.0
evaporating pressure below which the compressor is
switched off during the pump down
h11
0
250
min
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
3
3
high superheating alarm delay (code “HSH”) and
operative low pressure alarm delay (code “LOP”)
h12
0
1
- - - -
not
avail.
not
avail.
non
disp.
non
disp.
non
disp.
non
disp.
0
0
enabling the low pressure alarm (code “LP”)
1
= YES
h13
-0.5
45.0
bar g /
PSI g (4)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0.0
0.0
evaporating pressure below which the lower pressure
alarm is activated (code “LP”) (44)
h14
0
250
min
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
3
3
low pressure alarm delay (code “LP”)