EVCO EVB1256N9D User Manual

Page 58

background image

EVCO S.p.A.

EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134

page 58 of 92

F8

0.1 (5)

15.0

°C/°F

(1)

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

F1 differential

F9

0

240

s

0

0

0

0

0

0

0

0

delay in the switching off of evaporator fan following the

switching off of the compressor (only if F0 = 2, 4 and 5)

F11

0.0

99.0

°C/°F

(1)

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

temperature of the condenser above which the condenser

fan is switched on (“F11 + 2,0 °C/4 °F, only if u1 and/or

u11 = 6) (29) (30)

F12

0

240

s

30

30

30

30

30

30

30

30

delay in the switching off of condenser fan following the

switching off of the compressor (only if u1 and/or u11 =

6)

F13

0

240

sx10

30

30

30

30

30

30

30

30

duration of evaporator fan switch off during “energy

saving” function, see also F14, i10, H01... H14 (only if F0

= 1, 2, 3 or 4)

F14

0

240

sx10

30

30

30

30

30

30

30

30

duration of evaporator fan switch on during “energy

saving” function, see also F13, i10, H01... H14 (only if F0

= 1, 2, 3 or 4)