EVCO EVB1256N9D User Manual
Page 50

EVCO S.p.A.
EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134
page 50 of 92
d4
0
1
- - - -
0
0
0
0
0
0
0
0
defrosting when device is switched on (only if d8 = 0, 1, 2
or 3) (8)
1
=
YES
d5
0
99
min
0
0
0
0
0
0
0
0
if d4 = 0, minimum time between switching on of device
and activation of defrosting (8)
if d4 = 1, delay in activation of defrosting after device is
switched on (8)
d6
0
2
- - - -
1
1
1
1
1
1
1
1
temperature displayed during defrosting (only if P5 = 0)
0
=
room temperature or CPT temperature
1
=
if
on
activation
of
defrosting,
the
room
temperature or CPT temperature is below the
“work set point + t”, at maximum “ work set point
+ t”; if on activation of defrosting, the room
temperature or CPT temperature is above “work
set point + t”, at maximum the room temperature
or CPT temperature on activation of defrosting
(14) (15)
2
= indication “dEF” (16)
d7
0
15
min
2
2
2
2
2
2
2
2
during dripping the compressor will remain switched off
and the defrosting output will remain deactivated; if d16
= 0, evaporator fan activity will depend on parameter F2;
if d16 0, the evaporator fan will remain switched off)