Device Preparation for NS-Link

Device Preparation for NS-Link

Use the appropriate table to verify that your hardware was installed properly and
is ready for NS-Link installation. See the hardware installation documentation
(Page 6) if you need to install the hardware.

DeviceMaster Serial Hub LEDs (below)

DeviceMaster RTS LEDs

on Page 10

DeviceMaster PRO LEDs

on Page 11

RocketPort Serial Hub ia LEDs

on Page 11

RocketPort Serial Hub Si LEDs

on Page 11

DeviceMaster Serial
Hub LEDs

Use this table to verify that your DeviceMaster Serial Hub is ready for NS-Link
installation.

Model

How to tell if the DeviceMaster Serial Hub is working
properly:

DeviceMaster

Serial Hub 8

The PWR LED on the front of the unit is lit, which indicates
it has power and has completed the boot cycle.

Note: The PWR LED flashes while booting and it takes

approximately 15 seconds for the bootloader to
complete the cycle.

The red LNK/ACT LED is lit, which indicates a working
Ethernet connection.

If the red 100 LED is lit, it indicates a working 100 MB
Ethernet connection (100 MB network, only).

DeviceMaster

Serial Hub 16

The Status LED on the front of the unit is lit, which indicates
it has power and has completed the boot cycle.

Note: The Status LED flashes while booting and it takes

approximately 15 seconds for the bootloader to
complete the cycle.

The red LNK/ACT LED is lit, which indicates a working
Ethernet connection.

If the red Duplex LED is lit, it indicates full-duplex activity.

If the red 100 LED is lit, it indicates a working 100 MB
Ethernet connection (100 MB network, only).