H setup parameter list, Appendix h setup parameter list – KEYENCE N-400 User Manual
Page 145

137
Appendices
Appendices
Appendix H
Setup Parameter List
HOST MODE
TRIGGER SETUP (Effective in multi-head mode only)
PROTOCOL SETUP
Mode
❑
Multi-drop link mode
❑
Multi-head mode
Interference suppression
❑
Disable
❑
Enable
Trigger ON time for
( )
interference suppression
* 10 ms to 2550 ms
Reading mode
❑
Single label
❑
Multi label 1
❑
Multi label 2
Data-send timing
❑
After reading
❑
At trigger OFF
Read error code
( )
* Up to eight characters
Trigger input signal type
❑
Level
❑
One-shot
One-shot input time
( )
* 100 ms to 25.5 s
Input time
❑
2 ms
❑
10 ms
State
❑
Normally-open
❑
Normally-closed
Trigger ON command
( )
* Up to eight characters
Trigger OFF command
( )
* Up to eight characters
PLC link
❑
Disable Handshaking
❑
No handshaking
❑
PASS/RTRY
❑
ACK/NAK
Header
❑
None
❑
STX
❑
ESC
❑
Custom ( ) * Up to five characters
Delimiter
❑
CR
❑
CR + LF
❑
ETX
❑
Custom ( ) * Up to five characters
Add ID
❑
Do not add
❑
Add
Checksum
❑
Do not add
❑
Add
❑
Enable
PLC model name
❑
SYSMAC-C
❑
MELSEC-A
❑
KV
PLC trigger area
❑
Disable
❑
Enable
DM head address
( ) 00
* 0000 to 9900
PLC station/
( )
* 000 to 255
unit number
File register
❑
Disable
❑
Enable
File register
( )
* 000 to 255
block number