A specifications, Appendix a specifications – KEYENCE N-400 User Manual
Page 128

Appendices
120
Appendices
Appendix A
Specifications
N-400
Model
N-400
Connectable bar code reader
BL-700 series, BL-500 series, BL-180 series
Rated input
15 to 26 VDC, 10 mA max.
Max. OFF current
1.0 mA
RS-232C
Applied standards
EIA, RS-232C standards
Synchronization
Start-stop (full-duplex)
Transmission code
ASCII code
Baud rate
600/1200/2400/4800/9600/19200/31250/38400bps
Data length
7 or 8 bits
Parity check
Even/Odd/None
Stop bit length
1 or 2 bits
RS-485
Applied standards
EIA, RS-485 standards
Synchronization
Start-stop (full-duplex)
Transmission code
ASCII code
Baud rate
600/1200/2400/4800/9600/19200/31250/38400 bps
Data length
7 or 8 bits
Parity check
Even/Odd/None
Stop bit length
1 or 2 bits
Max. number of
31
connectable units
Max. total
1.2 km
extension distance
Ambient temperature
0 to 50
°
C (32 to 122
°
F), No freezing
Relative humidity
35 to 85%, No condensation
Ambient atmosphere
No dust or corrosive gas
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude in
X, Y and Z directions, respectively
Power supply voltage
24 VDC +10%/-20%
Current consumption
140 mA max.
Weight
Approx. 180 g
Trigger
input