Appendices program for the kv series, Appendices – KEYENCE N-400 User Manual
Page 138

Appendices
130
Appendices
Program for the KV series
Specify the head address of the data
memory area for each ID number.
Specify the data memory flag for each
ID number as “2”. (To use the flag,
select “Sequential processing”.)
Enter “0000” for the reading trigger
input of ID No. 1.
Enter “0001” for the reading trigger
input of ID No. 2.
Enter “0002” for the reading trigger input
of ID No. 3.
When DM0100 becomes “3”, the
specified processing is performed.
After processing is completed, enter “2”
in DM0100.
When DM0200 becomes “3”, the
specified processing is performed.
After processing is completed, enter “2”
in DM0200.
When DM0300 becomes “3”, the
specified processing is performed.
After processing is completed, enter “2”
in DM0300.
2008
ENDH
END
#0100
DW
DM0000
#0200
DW
DM0001
#0300
DW
DM0002
#0002
DW
DM0100
0000
#0001
DW
DM0031
0000
#0000
DW
DM0031
0001
#0100
DW
DM0032
0001
#0000
DW
DM0032
0002
#0001
DW
DM0033
0002
#0000
DW
DM0033
2002
#0100
LDA
2010
#0002
DW
DM0100
2002
DM0200
LDA
2010
#0002
DW
DM0200
2002
DM0300
LDA
2010
#0002
DW
DM0300
#0003
CMP
#0002
DW
DM0300
#0002
DW
DM0200
#0003
CMP
#0003
CMP
[Data stored in DM0103 and subsequent
areas is processed.]
[Data stored in DM0203 and subsequent
areas is processed.]
[Data stored in DM0303 and subsequent
areas is processed.]