Chapter 5 Multi-Head Mode Control Procedure

98

5

5.6

Communication Time

The following is the operation timing chart for “Single label” reading in multi-head
mode. This operation timing chart shows the case in which only one BL series
succeeded in reading bar code data. When several BL series simultaneously read
bar code data, the communication time may be longer than the following data.

Reading start delay time (F)

When the trigger input connected to the N-400 is turned ON in multi-head mode,
the N-400 sends the “Reading start (LON)” command to all connected units.
Therefore, the start of the BL series’ reading operations is delayed by the time
duration until the command transmission to all the BL series is completed.

The communication time required to send the reading start command to one BL
series is as follows:

When the number of connected BL series is “n”, the communication time is
calculated as follows:

F = D x n

* n = Number of connected BL series

Serial output maximum delay time (G)

The serial output maximum delay time is the maximum delay time until the N-400
sends bar code data to the host computer after the BL series reads the data.

When the RS-485 communication baud rate is 38400 bps:

Baud rate (RS-485)

Reading start delay time (D)

9600 bps

31 ms

38400 bps

13.5 ms

Serial output maximum delay time (G)

Number of data

Number of data

Number of data

digits: 10

digits: 20

digits: 32

2

96 ms

106 ms

116 ms

5

258 ms

268 ms

278 ms

10

528 ms

538 ms

548 ms

20

1,068 ms

1,078 ms

1,088 ms

31

1,662 ms

1,672 ms

1,682 ms

Number of
connected BL
series

F

F

H

G

I

Trigger input to
the N-400

Reading operation

N-400 <-> Host
computer (RS-232C)

Reading starts. The BL series read

bar code data.