80 Chapter
5
•
•
•
•
•
•
Printer Command Parameters
RS-232 printer configuration.
The Printer Mode selects what will be transmitted to the serial printer over the RS-232
interface
•
Gross Weight (default)
•
Net Weight
•
Tare Weight
•
Unit Count
•
All – Gross, Net, Tare, and Count
•
(if Count enabled) values
•
OFF, Printer disabled.
If the Count Mode is not enabled, the option to select count is disabled, and if the “All”
option is selected, the Unit Count value is not printed.
Selecting the “OFF”, Printer Mode option disables the print function.
If any other option is selected when the display is at the summary page level, pressing the
ENTER key is sending the selected weight values over the serial interface to the printer.