2 Configuration environment setup
Nortel Secure Router 8000 Series
Configuration Guide - Basic Configuration
Figure 2-1 Networking diagram of logging on through the console port
PC
Router
Configuration roadmap
•
Connect the PC and the router through the console port.
•
Configure the parameters on the PC end.
•
Log on to the router.
Data preparation
•
terminal communication parameters (including baud rate, data bit, parity, stop bit, and
flow control)
Configuration procedure
Step 1 Connect the serial port of the PC (or terminal) to the console port of the router through
standard RS-232 configuration cable. The local configuration environment is established.
Step 2 Run the terminal emulation program on the PC. Configure the terminal communication
parameters to 9600 bps, data bit to 8, and stop bit to 1. Specify no parity and no flow control
as shown in Figure 2-2 to Figure 2-4.