4 port-level policing – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual
Page 75

9145EMP NID Software User’s Manual
Port Information
Port Configuration
60
5.2.4 Port-level Policing
For more information on 9145EMP policers, see the section “Policers” on page 200.
To configure port-level policing, select Port Level Policers (4) from the Port Configuration screen
and press Enter. The Port Policing screen (Figure 5-9) opens.
Figure 5-9 Port Policing screen
1. On the Port Policing screen, type the port number (1 to 4), and press Enter. The Modify
Port Policing Attributes screen (Figure 5-10) for that port opens.
Figure 5-10 Modify Port Policing Attributes screen
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 10:14:38
--------------------------------PORT POLICING----------------------------------
Policing Policer Bandwidth Profile
-------- ------- -----------------
1) User Port 1: Enabled 22 121 (17236326545)
2) User Port 2: Disabled N/A N/A
3) User Port 3: Enabled 33 N/A (17236326565)
4) User Port 4: Disabled N/A N/A
Select [1-4]:
------------------------------------Messages-----------------------------------
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 10:14:38
-----------------------MODIFY PORT POLICING ATTRIBUTES--------------------------
USER PORT 1
1) Port Level Policing : Enabled
2) Policer : 10
3) Bandwidth Profile: 1
Select [1-3] for attributes:
------------------------------------Messages-----------------------------------