10.2 CoS Support
To begin configuring Class of Service, from the Main Menu, select CoS Configuration (10) and
press Enter. The Class of Service Configuration screen (Figure 10-2) opens.
Figure 10-2 Class of Service Configuration screen
10.2.1 Enabling or Disabling CoS Support
To enable or disable CoS support for a port, from the CoS Configuration screen (Figure 10-2),
type the number of the port you wish to configure (1 or 2) and press Enter. The setting is
highlighted. Press the Space bar to select Enabled or Disabled and then press Enter.
When CoS is enabled on a given port, frames egressing on that port are subjected to queue
processing.
Press Esc to return to the Class of Service Configuration screen.
Canoga Perkins Corp. Ethernet Network Interface Device 21-MAR-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
------------------------CLASS OF SERVICE CONFIGURATION--------------------------
1) CoS Support on User Port Enabled
2) CoS Support on Network Port Disabled
3) CoS Queues Configuration
4) CoS Queues Statistics
Select [1-4]:
------------------------------------Messages-----------------------------------