9145EMP NID Software User’s Manual
System Configuration
IP/SNMP Agent Configuration
16
Tagged), S-Tagged, or S-T-C Tagged. The value defaults to 0 if any of the other type of
tagging modes are selected.
7. Auxiliary VLAN Tagging on User ports Describes the tagging mode for the frames sent
and received when the Auxiliary IP address is configured on any of the User Ports.
Options are Untagged or C-Tagged.
8. Auxiliary C-VLAN ID on User ports Sets the C-VLAN ID value (between 1 and 4094) for
the C-Tags on User Ports. Valid if the Auxiliary VLAN Tagging mode on User Ports is set
to C-Tagged.
9. Allow any VLAN If this option is enabled, frames addressed to the Auxiliary IP address
are processed regardless of their VLAN tagging. All responses on such frames are
tagged with the received VLAN ID. Frames initiated by the NID will be still tagged with the
configured encapsulation (Options 3 to 7 above). If this option is disabled, received
frames will only be processed if they have the VLAN ID set on this screen.
10. Auxiliary IP Rate Limiting Specifies whether the maximum limit of 500 frames per
second is enforced for frames received on the Auxiliary IP address.