5 normal mode commands, Normal mode commands, H 10-10 – Rice Lake 720i Programmable Indicator/Controller - Installation Manual User Manual
Page 99

Serial Commands
93
Table 10-9. Setpoint Serial Commands
10.1.5
Normal Mode Commands
The normal mode print commands (see Table 10-10) transmit data to the serial port on demand in either setup or
normal mode.
SP.SENSE#n
Digital output sense
NORMAL, INVERT
SP.BRANCH#n
Branch destination
0, 1-32
SP.RELNUM#n
Relative setpoint number
1–32
SP.START#n
Starting setpoint
1–32
SP.END#n
Ending setpoint
1–32
SP.DISLOT#n
Digital input slot
NONE, SLOTx
SP.MASK#n
Digital input mask
number
SP.NSAMPLE#n
Number of samples
number
SP.TIME#n
Trip time
hhmm
SP.DURATION#n
Trip duration
hhmmss
SP.VUNDER#n
Underrange value
number
SP.VOVER#n
Overrange value
number
SP.DUNDER#n
Underrange digital output
BITx
SP.DACCEPT#n
Accept digital output
BITx
SP.DOVER#n
Overrange digital output
BITx
BATCHNG
Batching mode
OFF, AUTO, MANUAL
SP.ENABLE#n
Setpoint enable
ON, OFF
For setpoint commands ending with “#n”, n is the setpoint number.
Command
Description
Values
CONSNUM
Set consecutive number
0–9 999 999
UID
Set unit ID
nnnnnnn
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST
Set time
hhmm (enter using 24-hour format)
CONTRAST
Set display contrast
0–127
SX#p
Start serial port streaming
OK or ??
The port streaming parameter (EDP.STREAM#p) for the
streaming port must be set to LFT or INDUST before using
these commands.
An EX command sent while in setup mode does not take
effect until the indicator is returned to normal mode.
EX#p
Stop serial port streaming
RS
Reset system
Soft reset. Used to reset the indicator without resetting the
configuration to the factory defaults.
SF#n
Transmit single frame of stream
Sends a single frame from scale n to the streaming port.
XA#1
Transmit accumulator value in displayed units
nnnnnn UU
XAP#1
Transmit accumulator value in primary units
XAS#1
Transmit accumulator value in secondary units
XAT#1
Transmit accumulator value in tertiary units
Table 10-10. Normal Mode Serial Commands
Command
Description
Values