8 battery replacement, 9 replacement parts and assembly drawings, 1 universal model – Rice Lake 720i Programmable Indicator/Controller - Installation Manual User Manual
Page 17: Universal model
Installation
11
2.8
Battery Replacement
The lithium battery on the CPU board maintains the
real-time clock and protects data stored in the system
RAM when the indicator is not connected to AC power.
Data protected by the CPU board battery includes time
and date, truck and tare memory, and onboard database
information.
Use
Revolution III
™
to store a copy of the indicator
configuration on a PC before attempting battery
r e p l a c e m e n t . I f a n y d at a i s l o s t , t h e i n d i c a t o r
configuration can be restored from the PC.
Watch for the low battery warning on the LCD display
and periodically check the battery voltage on both the
CPU board and on any installed memory option cards.
Batteries should be replaced when the indicator low
battery warning comes on, or when battery voltage falls
to 2.2 VDC. Life expectancy of the battery is ten years.
Replacement Procedure
For best results, replace the battery while in weigh
mode and with AC power applied. Use care not to
bend the battery retaining spring.
If the battery must be replaced with power removed, do
the following immediately after restoring power:
1. Place indicator in setup mode.
2. Go to the Version menu and press the
RSConfig
softkey. If connected using
Revolution III
,
configuration can be reset by using monitor
mode to enter the RESETCONFIGURATION
command followed by the RS command.
See Figure 2-3 on page 9 for CPU board battery
location and orientation (positive side up).
WARNING
Risk of explosion if battery is replaced
with incorrect type. Dispose of batteries
per manufacturer instruction.
2.9
Replacement Parts and Assembly Drawings
2.9.1
Universal Model
Table 2-6 lists replacement parts and parts kit contents for the
720i
universal enclosure model, including all parts
referenced in Figures 2-6 through 2-8.
Ref Number
PN
Description (Quantity)
See Figure
1
101257
Switch panel membrane, universal (1)
2
53308
Model/serial number label (1)
3
101263
Enclosure, universal (1)
4
103988
Tilt stand washers (2), in parts kit
5
103610
Tilt stand knobs (2), in parts kit
6
67531
Tilt stand (1)
7
15628
Cord grip, 1/2 NPT (1)
8
15626
Cord grips, PG9 (3)
9
15630
Lock nut for 1/2 NPT cord grip (1)
10
68600
Cord grip, PG11 (1)
11
15627
Lock nuts, PCN9 (3)
12
68601
Lock nut, PG11 (1)
13
45043
Ground wire, 4 in w/ No. 8 eye connector (1)
14
102887
Display board assembly, universal (1)
15
85202
Power cord assembly, 115 VAC and 230 VAC North American units (1)
85203
Power cord assembly, 230 VAC European units (1)
—
16
67885
Standoffs, M-F, 4-40NC x 3/4 (2)
17
14618
Kep nuts, 4-40NC hex (3)
18
103443
CPU board mounting strip (1)
19
106788
720i
CPU board (PCE Version) (1)
20
102376
Backplate gasket, universal (1)
21
75062
Sealing washers (4)*
22
14862
Machine screws, 8-32NC x 3/8 (4)*
Table 2-6. Universal Model Replacement Parts