6 batching control commands, Batching control commands – Rice Lake 720i Programmable Indicator/Controller - Installation Manual User Manual
Page 100

94
720i Installation Manual
10.1.6
Batching Control Commands
The commands listed in Table 10-11 provide batching control through the serial port
Table 10-11. Batching Control Commands
Command
Description
Values
BATSTART
Batch start
If the BATRUN digital input is active (low) or not assigned, the BATSTART
command can be used to start the batch program.
BATSTOP
Batch stop
Stops the batch program and turns off all associated digital outputs.
BATPAUSE
Batch pause
Stops the batch program at the current step. All digital outputs set on by the
current step (except for those set by concur setpoints) are set off. The BATSTRT
DIGIN, BATSTART serial command, or the Batch Start softkey.
BATRESET
Batch reset
Stops the program and resets the batch program to the first batch step. Run the
BATRESET command after making changes to the batch configuration.
BATSTATUS
Batch status
• S000 Stopped at SP0
• R003 Running at SP3
• P004 Paused at SP4
Note
The following batch control commands only apply to the 720i Batch Version Software only.
XG#1
Transmit gross weight in displayed units
nnnnnn UU
XGP#1
Transmit gross weight in primary units
XGS#1
Transmit gross weight in secondary units
XGT#1
Transmit gross weight in tertiary units
XN#1
Transmit net weight in displayed units
nnnnnn UU
XNP#1
Transmit net weight in primary units
XNS#1
Transmit net weight in secondary units
XNT#1
Transmit net weight in tertiary units
XT#1
Transmit tare weight in displayed units
nnnnnn UU
XTP#1
Transmit tare weight in primary units
XTS#1
Transmit tare weight in secondary units
XTT#1
Transmit tare weight in tertiary units
XE
Query system error conditions
nnnnn
See Section 11.1.5 on page 100 for detailed information
about the XE command response format.
Command
Description
Values