Rice Lake 720i Programmable Indicator/Controller - Installation Manual User Manual
Page 94
88
720i Installation Manual
SC.DFTHRH#1
Digital filter cutout threshold
NONE, 2D, 5D, 10D, 20D, 50D, 100D, 200D, 250D
SC.RATLTRAP#1
Rattletrap filtering
OFF, ON
SC.SMPRAT#1
Sample rate
7.5HZ, 15HZ, 30HZ, 60HZ, 120HZ, 240HZ, 480HZ, 960HZ
SC.PWRUPMD#1
Power up mode
GO, DELAY
SC.TAREFN#1
Tare function
BOTH, NOTARE, PBTARE, KEYED
SC.PRI.DECPNT#1
Primary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800
SC.PRI.DSPDIV#1
Primary units display divisions
1D, 2D, 5D
SC.PRI.UNITS#1
Primary units
LB, KG, G, OZ, TN, T, GR, troyoz, troylb, LT, CUSTOM, NONE,
OFF
SC.PRI.CUNITS#1
Primary custom units
Specify units if SC.PRI.UNITS=CUSTOM
SC.SEC.DECPNT#1
Secondary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800
SC.SEC.DSPDIV#1
Secondary units display divisions
1D, 2D, 5D
SC.SEC.UNITS#1
Secondary units
LB, KG, G, OZ, TN, T, GR, troyoz, troylb, LT, CUSTOM, NONE,
OFF
SC.SEC.CUNITS#1
Secondary custom units
Specify units if SC.SEC.UNITS=CUSTOM
SC.SEC.MULT#1
Secondary units multiplier
0.00000–9999999
SC.TER.UNITS#1
Tertiary units
LB, KG, G, OZ, TN, T, GR, troyoz, troylb, LT, CUSTOM, NONE,
OFF
SC.TER.CUNITS#1
Tertiary custom units
Specify units if SC.TER.UNITS=CUSTOM
SC.TER.DECPNT#1
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800
SC.TER.DSPDIV#1
Tertiary units display divisions
1D, 2D, 5D
SC.TER.MULT#1
Tertiary units multiplier
0.000001–9999999
SC.ROC.DECPNT#1
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800
SC.ROC.DSPDIV#1
Rate-of-change units display divisions
1D, 2D, 5D
SC.ROC.MULT#1
Rate-of-change units multiplier
0.000001–9999999
SC.ROC.UNITS#1
Rate-of-change units
SEC, MIN, HOUR
SC.ROC.INTERVL#1
Rate-of-change interval
1–100
SC.ROC.REFRESH#1
Rate-of-change refresh interval
0.1–60
SC.RANGE1.MAX#1
Weight maximum for first range or
interval
weight
SC.RANGE2.MAX#1
Weight maximum for second range or
interval
weight
SC.RANGE3.MAX#1#1
Weight maximum for third range or
interval
weight
SC.ACCUM#1
Accumulator enable
ON, OFF
SC.VISIBLE#1
Scale visibility
ON, OFF
SC.PEAKHOLD#1
Peak hold
OFF, NORMAL, BI-DIR, AUTO
SC.WZERO#1
Zero calibration
—
SC.WVAL#1
Test weight value
test_weight_value
SC.WSPAN#1
Span calibration
—
SC.WLIN.F1#1–
SC.WLIN.F5#1
Actual raw count value for linearization
points 1–5
0–16777215
Command
Description
Values
Table 10-3. SCALES Serial Commands (Continued)