Table 3-9. DIG I/O Menu Parameters
DIG I/O Menu
Parameter
Choices
Description
Level 2 submenus
SLOTx
BIT y
Lists available digital I/O slots.
Level 3 submenus
BIT y
OFF
INPUT
OUTPUT
ZERO
NT/GRS
TARE
UNITS
PRINT
ACCUM
SETPTS
TIMDATE
ESC
CLEAR
DSPTAR
KEY0—KEY9
KEYDP
ENTER
NAVUP
NAVDN
NAVLFT
NAVRGT
KBDLOC
HOLD
*BATRUN
*BATSTRT
*BATPAUS
*BATRESET
*BATSTOP
CLRCN
GROSS
NET
PRIM
SEC
TER
CLRTAR
CLRACC
Specifies the function of the digital I/O bit.
• OFF indicates that the bit is not configured.
• INPUT assigns the bit as a digital input.
• OUTPUT assigns the bit as a digital output.
• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same
functions as the five major front panel keys.
• ACCUM adds the current scale weight to the accumulator, if the scale accumulator is
enabled.
• SETPTS and TIMDATE provide the same function as the Setpoint and Time/Date softkeys.
• TIMDATE provides the same function as the Time/Date softkey.
• ESC provides a function equivalent to the Cancel softkey.
• CLEAR simulates pressing the front panel CLR key.
• DSPTAR displays the current tare; equivalent to pressing the Display Tare softkey.
• KEY0—KEY9 and KEYDP (decimal point) simulate pressing keys on the numeric keypad.
• ENTER simulates pressing the front panel ENTER key.
• NAVUP, NAVDN, NAVLFT, and NAVRGT simulate pressing the navigation keys.
• KBDLOC locks the keyboard (indicator front panel) when held low.
• HOLD holds the current display. Releasing this input clears the running average filter.
• BATRUN allows a batch routine to be started and run. With BATRUN active (low), the
BATSTRT input starts the batch; if BATRUN is inactive (high), BATSTRT resets the batch.
• BATSTRT starts or resets a batch routine, depending on the state of the BATRUN input.
• BATPAUS pauses a batch routine when held low.
• BATRESET stops the batch sequence and resets to the first batch step.
• BATSTOP stops the batch routine.
• CLRCN resets the consecutive number to the value specified on the CONSTUP parameter
(FEATURE menu).
• GROSS, NET, PRIM, SEC, and TER select gross or net weight display, and primary,
secondary, or tertiary units display modes.
• CLRTAR clears the current tare for the active scale.
• CLRACC clears the active accumulator.
* 720i Batching Software Version Only
44
720i Installation Manual