Configuration

41

FEATURE Menu, REGULAT/INDUST Submenu

The INDUST setting of the REGULAT parameter allows customization of several tare, clear, and print functions
for use in non-legal-for-trade scale installations. See Section 11.2 on page 101 for more information about
regulatory mode functions.

REGULAT

SNPSHOT

DISPLAY

INDUST

SCALE

HTARE

NO

YES

ZTARE

NO

YES

KTARE

YES

NO

MTARE

REPLACE

REMOVE

NOTHING

NTARE

NO

YES

CTARE

YES

NO

PRTMOT

NO

YES

PRTPT

NO

YES

PRTHLD

NO

YES

HLDWGH

NO

YES

MOTWGH

NO

YES

AUDAGNCY

NTEP

CANADA

INDUST

NONE

OIML

OVRBASE

CALIB

SCALE

SCALES

SERIAL

FEATURE

PFORMT

DIG I/O

ALGOUT

VERS

SETPTS

720i Batching

Version only

see page 57

Figure 3-14. REGULAT / INDUST Submenu

Table 3-8. REGULAT / INDUST Submenu Parameters

FEATURE Menu, REGULAT / INDUST Submenu

Parameter

Choices

Description

Level 4, REGULAT / INDUST submenu

SNPSHOT

DISPLAY, SCALE

Display or Scale weight source.

HTARE

NO, YES

Allow tare in display hold

ZTARE

NO, YES

Remove tare on ZERO

KTARE

YES, NO

Always allow keyed tare

MTARE

REPLACE
REMOVE
NOTHING

Multiple tare action

NTARE

NO, YES

Allow negative or zero tare

CTARE

YES, NO

Allow CLEAR key to clear tare/accumulator

PRTMOT

NO, YES

Allow print while in motion

PRTPT

NO, YES

Add PT to keyed tare print

PRTHLD

NO, YES

Print during display hold

HLDWGH

NO, YES

Allow truck weighment during display hold

MOTWGH

NO, YES

Allow truck weighment in motion

OVRBASE

CALIB, SCALE

Zero base for overload calculation

AUDAGNCY

NTEP
CANADA
INDUST
NONE
OIML

Audit trail display agency format.