Setpoints

67

TOD

Time of day setpoint. Performs functions when the internal clock time of the
indicator matches the specified setpoint time.

X

X

DELTA

Delta weight setpoint. Satisfied when the change in weight on the scale is equal to
or exceeds the absolute value specified for the setpoint.

X

CHKWEI

Checkweigher setpoint. Allows specification of over- and under-weight values. Up
to three digital outputs can be configured to represent overweight, underweight,
and accept conditions.

X

ALWAYS

Always setpoint. This setpoint is always satisfied. It is typically used to provide an
endpoint for true/false branching batch routines.

X

NEVER

Never setpoint. This setpoint is never satisfied. It is used to branch to a
designated setpoint in true/false branching batch routines in which the batch will
not continue through the normal sequence of batch setpoints.

X

Kind

Description

Batch

Continuous

Table 8-1. Setpoint Kinds (Continued)