beautypg.com

Dell PowerEdge FX2/FX2s User Manual

Page 211

background image

Example of Syslog Messages Before and After Entering the clear ufd-disable uplink-state-
group
Command

The following example message shows the Syslog messages that display when you clear the UFD-
Disabled state from all disabled downstream interfaces in an uplink-state group by using the clear
ufd-disable uplink-state-group group-id command. All downstream interfaces return to an
operationally up state.

00:10:12: %STKUNIT0-M:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to

down: Te 0/1

00:10:12: %STKUNIT0-M:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to

down: Te 0/2

00:10:12: %STKUNIT0-M:CP %IFMGR-5-ASTATE_DN: Changed interface Admin state to

down: Te 0/3

00:10:12: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/1

00:10:12: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/2

00:10:12: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/3

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed uplink state group state

to down: Group

3

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD

error-disabled:

Te 0/4

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD

error-disabled:

Te 0/5

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Downstream interface set to UFD

error-disabled:

Te 0/6

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/4

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/5

00:10:13: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down:

Te 0/6

Dell(conf-if-range-te-0/1-3)#do clear ufd-disable uplink-state-group 3

00:11:50: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from

UFD

error-disabled: Te 0/4

00:11:51: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from

UFD

error-disabled: Te 0/5

00:11:51: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Downstream interface cleared from

UFD

error-disabled: Te 0/6

00:11:51: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te

0/4

00:11:51: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te

0/5

00:11:51: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te

0/6

Uplink Failure Detection (UFD)

211