NPIV Proxy Gateway: Terms and Definitions

The following table describes the terms used in an NPG configuration on the Aggregator.

Table 20. Aggregator with the NPIV Proxy Gateway: Terms and Definitions

Term

Description

FC port

Fibre Channel port on the Aggregator that operates in autosensing, 2, 4,

or 8-Gigabit mode. On an NPIV proxy gateway, an FC port can be used

as a downlink for a server connection and an uplink for a fabric

connection.

F port

Port mode of an FC port connected to an end node (N) port on an

Aggregator with the NPIV proxy gateway.

N port

Port mode of an Aggregator with the FC port that connects to an F port

on an FC switch in a SAN fabric. On an Aggregator with the NPIV proxy

gateway, an N port also functions as a proxy for multiple server CNA-

port connections.

ENode port

Port mode of a server-facing Aggregator with the Ethernet port that

provides access to FCF functionality on a fabric.

CNA port

N-port functionality on an FCoE-enabled server port. A converged

network adapter (CNA) can use one or more Ethernet ports. CNAs can

encapsulate Fibre Channel frames in Ethernet for FCoE transport and de-

encapsulate Fibre Channel frames from FCoE to native Fibre Channel.

DCB map

Template used to configure DCB parameters, including priority-based

flow control (PFC) and enhanced transmission selection (ETS), on CEE

ports.

Fibre Channel fabric

Network of Fibre Channel devices and storage arrays that inter-operate

and communicate.

FCF

Fibre Channel forwarder: FCoE-enabled switch that can forward FC

traffic to both downstream FCoE and upstream FC devices. An NPIV

proxy gateway functions as an FCF to export upstream F port

configurations to downstream server CNA ports.

FC-MAP

FCoE MAC-address prefix — The unique 24-bit MAC address prefix in

FCoE packets used to generate a fabric-provided MAC address (FPMA).

The FPMA is required to send FCoE packets from a server to a SAN fabric.

FCoE map

Template used to configure FCoE and FC parameters on Ethernet and

FC ports in a converged fabric.

FCoE VLAN

VLAN dedicated to carrying only FCoE traffic between server CNA ports

and a SAN fabric. (FCoE traffic must travel in a VLAN.) When you apply an

FCoE map on a port, FCoE is enabled on the port. All non-FCoE traffic is

dropped on an FCoE VLAN.

FIP

FCoE Initialization Protocol: Layer 2 protocol for endpoint discovery,

fabric login, and fabric association. FIP is used by server CNAs to discover

NPIV Proxy Gateway

251