Description

Behavior at Peer Up

Behavior During Run

Time

Action to Take

System MAC mismatch

A syslog error message
and an SNMP trap are
generated.

A syslog error message
and an SNMP trap are
generated.

Verify that the unit ID of
VLT peers is not the
same on both units and
that the MAC address is
the same on both units.

Unit ID mismatch

The VLT peer does not

boot up. The VLTi is

forced to a down state.

A syslog error message

is generated.

The VLT peer does not

boot up. The VLTi is

forced to a down state.

A syslog error message

is generated.

Verify the unit ID is
correct on both VLT
peers. Unit ID numbers
must be sequential on
peer units; for example,
if Peer 1 is unit ID “0”,
Peer 2 unit ID must be
“1’.

Version ID mismatch

A syslog error message
and an SNMP trap are
generated.

A syslog error message
and an SNMP trap are
generated.

Verify the Dell
Networking OS software
versions on the VLT
peers is compatible. For
more information, refer
to the Release Notes for
this release.

VLT LAG ID is not
configured on one VLT
peer

A syslog error message
is generated. The peer
with the VLT configured
remains active.

A syslog error message
is generated. The peer
with the VLT configured
remains active.

Verify the VLT LAG ID is
configured correctly on
both VLT peers.

VLT LAG ID mismatch

The VLT port channel is

brought down.

A syslog error message

is generated.

The VLT port channel is

brought down.

A syslog error message

is generated.

Perform a mismatch
check after the VLT peer
is established.

248

PMUX Mode of the IO Aggregator