Show fcoe-map command examples – Dell PowerEdge FX2/FX2s User Manual
Page 261
Te 0/1 Up 10000 Mbit Full 1-4094
Te 0/2 Down Auto Auto 1-1001,1003-4094
Te 0/3 Up 10000 Mbit Full 1-1001,1003-4094
Te 0/4 Down Auto Auto 1-1001,1003-4094
Te 0/5 Up 10000 Mbit Full 1-4094
Te 0/6 Up 10000 Mbit Full 1-4094
Te 0/7 Up 10000 Mbit Full 1-4094
Te 0/8 toB300 Down Auto Auto 1-1001,1003-4094
Fc 0/9 Up 8000 Mbit Full --
Fc 0/10 Up 8000 Mbit Full --
Te 0/11 Down Auto Auto --
Te 0/12 Down Auto Auto --
Table 22. show interfaces status Field Descriptions
Field
Description
Port
Server-facing 10GbE Ethernet (Te), or fabric-facing Fibre Channel (FC)
port with slot/port information.
Description
Text description of port.
Status
Operational status of port:
Ethernet ports - up (transmitting FCoE and LAN storage traffic) or down
(not transmitting traffic).
Fibre Channel ports - up (link is up and transmitting FC traffic) or down
(link is down and not transmitting FC traffic), link-wait (link is up and
waiting for FLOGI to complete on peer SW port), or removed (port has
been shut down).
Speed
Transmission speed (in Megabits per second) of Ethernet and FC ports,
including auto-negotiated speed (Auto).
Duplex
Data transmission mode: Full (allows communication in both directions
at the same time), Half (allows communication in both directions but
not at the same time), Auto (auto-negotiated transmission).
VLAN
VLAN IDs of the VLANs in which the port is a member.
show fcoe-map Command Examples
Dell# show fcoe-map brief
Fabric-Name Fabric-Id Vlan-Id FC-MAP FCF-Priority Config-
State Oper-State
fid_1003 1003 1003 0efc03 128
ACTIVE UP
fid_1004 1004 1004 0efc04 128
ACTIVE DOWN
Dell# show fcoe-map fid_1003
Fabric Name fid_1003
Fabric Id 1003
Vlan Id 1003
Vlan priority 3
FC-MAP 0efc03
FKA-ADV-Period 8
NPIV Proxy Gateway
261