Table 24. show qos dcb-map Field Descriptions
Field
Description
State
Complete: All mandatory DCB parameters are correctly configured. In
progress: The DCB map configuration is not complete. Some
mandatory parameters are not configured.
PFC Mode
PFC configuration in the DCB map: On (enabled) or Off.
PG
Priority group configured in the DCB map.
TSA
Transmission scheduling algorithm used in the DCB map: Enhanced
Transmission Selection (ETS).
BW
Percentage of bandwidth allocated to the priority group.
PFC
PFC setting for the priority group: On (enabled) or Off.
Priorities
802.1p priorities configured in the priority group.
show npiv devices brief Command Example
Dell# show npiv devices brief
Total NPIV Devices = 2
--------------------------------------------------------------------------------
------------------------
ENode-Intf ENode-WWPN FCoE-Vlan Fabric-Intf Fabric-Map
LoginMethod Status
--------------------------------------------------------------------------------
------------------------
Te 0/11 20:01:00:10:18:f1:94:20 1003 Fc 0/9
fid_1003 FLOGI LOGGED_IN
Te 0/12 10:00:00:00:c9:d9:9c:cb 1003 Fc 0/10
fid_1003 FDISC LOGGED_IN
Table 25. show npiv devices brief Field Descriptions
Field
Description
Total NPIV Devices
Number of downstream ENodes connected to a fabric over the
Aggregator with the NPG.
ENode-Intf
Aggregator with the Ethernet interface (slot/port) to which a server
CNA is connected.
ENode-WWPN
Worldwide port name (WWPN) of a server CNA port.
FCoE-Vlan
VLAN ID of the dedicated VLAN used to transmit FCoE traffic to and
from the fabric.
Fabric-Intf
Fabric-facing Fibre Channel port (slot/port) on which FC traffic is
transmitted to the specified fabric.