This view helps identifying the stack unit/port pipe/port that may experience internal drops.
• View the input and output statistics for a stack-port interface.
EXEC Privilege mode
show hardware stack-unit {0-5} stack-port {33–56}
• View the counters in the field processors of the stack unit.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} counters
• View the details of the FP Devices and Hi gig ports on the stack-unit.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} details
• Execute a specified bShell command from the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} execute-shell-cmd {command}
• View the Multicast IPMC replication table from the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} ipmc-replication
• View the internal statistics for each port-pipe (unit) on per port basis.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} port-stats [detail]
• View the stack-unit internal registers for each port-pipe.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} register
• View the tables from the bShell through the CLI without going into the bShell.
EXEC Privilege mode
show hardware stack-unit {0-5} unit {0-0} table-dump {table name}
Environmental Monitoring
Aggregator components use environmental monitoring hardware to detect transmit power readings,
receive power readings, and temperature updates.
To receive periodic power updates, you must enable the following command.
• Enable environmental monitoring.
enable optic-info-update interval
Example of the show interfaces transceiver Command
Dell#show interfaces tengigabitethernet 0/9 transceiver
SFP is present
SFP+ 9 Serial Base ID fields
SFP+ 9 Id = 0x03
SFP+ 9 Ext Id = 0x04
SFP+ 9 Connector = 0x21
SFP+ 9 Transceiver Code = 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x00
SFP+ 9 Encoding = 0x00
Debugging and Diagnostics