Field
Description
FCF MAC
Fibre Channel forwarder MAC: MAC address of Aggregator with the FCF
interface.
Fabric Intf
Fabric-facing Aggregator with the Fibre Channel port (slot/port) on
which FCoE traffic is transmitted to the specified fabric.
FCoE VLAN
ID of the dedicated VLAN used to transmit FCoE traffic from a server
CNA to a fabric and configured on both the server-facing Aggregator
with the server CNA port.
Fabric Map
Name of the FCoE map containing the FCoE/FC configuration
parameters for the server CNA-fabric connection.
Enode WWPN
Worldwide port name of the server CNA port.
Enode WWNN
Worldwide node name of the server CNA.
FCoE MAC
Fabric-provided MAC address (FPMA). The FPMA consists of the FC-
MAP value in the FCoE map and the FC-ID provided by the fabric after
a successful FLOGI. In the FPMA, the most significant bytes are the FC-
MAP; the least significant bytes are the FC-ID.
FC-ID
FC port ID provided by the fabric.
LoginMethod
Method used by the server CNA to log in to the fabric; for example,
FLOGI or FDISC.
Secs
Number of seconds that the fabric connection is up.
State
Status of the fabric connection: logged in.
show fc switch Command Example
Dell# show fc switch
Switch Mode : NPG
Switch WWN : 10:00:5c:f9:dd:ef:10:c0
Dell#
Table 27. show fc switch Command Description
Field
Description
Switch Mode
Fibre Channel mode of operation of an Aggregator. Default: NPG
(configured as an NPIV proxy gateway).
Switch WWN
Factory-assigned worldwide node (WWN) name of the Aggregator. The
Aggregator WWN name is not user-configurable.
NPIV Proxy Gateway
265