beautypg.com

Software show commands – Dell PowerEdge FX2/FX2s User Manual

Page 269

background image

U 1

T 2-4094

Native VlanId: 1

2.

Assign the port to a specified group of VLANs (vlan tagged command) and re-display the port mode

status..
Dell(conf)#interface tengigabitethernet 0/1

Dell(conf-if-te-0/1)#vlan tagged 2-5,100,4010

Dell(conf-if-te-0/1)#

Dell#show interfaces switchport tengigabitethernet 0/1

Codes: U - Untagged, T - Tagged

x - Dot1x untagged, X - Dot1x tagged

G - GVRP tagged, M - Trunk, H - VSN tagged

i - Internal untagged, I - Internal tagged, v - VLT untagged, V -

VLT tagged

Name: TenGigabitEthernet 0/1

802.1QTagged: Hybrid

SMUX port mode: Admin VLANs enabled

Vlan membership:

Q Vlans

U 1

T 2-5,100,4010

Native VlanId: 1

Software show Commands

Use the show version and show system stack-unit 0 commands as a part of troubleshooting an

Aggregator’s software configuration.

Table 28. Software show Commands

Command

Description

show version

Display the current version of Dell Networking OS software

running on an Aggregator.

show version Command Example
Dell#show version

Dell Real Time Operating System Software

Dell Operating System Version: 2.0

Dell Application Software Version: 9-4(0-180)

Copyright (c) 1999-2014 by Dell Inc. All Rights Reserved.

Build Time: Sun Mar 30 20:15:19 PDT 2014

Build Path: /work.local/build/toolSpaces/tools05/E9-4-0/SW/SRC

Dell Networking OS uptime is 9 hour(s), 21 minute(s)

System image file is "dv-ci-stomp-tc-1-a1"

System Type: PE-FN-410S-IOA

Control Processor: MIPS RMI XLP with 2147483648 bytes of memory, core(s) 1.

128M bytes of boot flash memory.

1 12-port GE/TE (FN)

Debugging and Diagnostics

269