beautypg.com

Deleting or disabling a port channel, Configuring auto lag – Dell PowerEdge FX2/FX2s User Manual

Page 125

background image

Dell(conf-if-te-0/2)#vlan tagged 2,3-4

2. Use the switchport command in INTERFACE mode to enable Layer 2 data transmissions through

an individual interface
INTERFACE mode

Dell(conf-if-te-0/2)#switchport

This switchport configuration is allowed only in PMUX mode. In all other modes, it is automatically
configured.

3. Verify the manually configured VLAN membership (show interfaces switchport interface command).

EXEC mode

Dell(conf)# interface tengigabitethernet 0/1

Dell(conf-if-te-0/1)#switchport

Dell(conf-if-te-0/1)# vlan tagged 2-5,100,4010

Dell#show interfaces switchport te 0/1

Codes: U - Untagged, T - Tagged

x - Dot1x untagged, X - Dot1x tagged

G - GVRP tagged, M - Trunk, H - VSN tagged

i - Internal untagged, I - Internal tagged, v - VLT untagged, V -

VLT tagged

Name: TenGigabitEthernet 0/1

802.1QTagged: True

Vlan membership:

Q Vlans

T 2-5,100,4010

Dell#

Deleting or Disabling a Port Channel

To delete or disable a port channel, use the following commands.

• Delete a port channel.

CONFIGURATION mode

no interface portchannel channel-number

• Disable a port channel.

shutdown

When you disable a port channel, all interfaces within the port channel are operationally down also.

Configuring Auto LAG

You can enable or disable auto LAG on the server-facing interfaces. By default, auto LAG is enabled. This
functionality is supported on the Aggregator in Standalone, Stacking, and VLT modes.
To configure auto LAG, use the following commands:

1.

Enable the auto LAG on all the server ports.
CONFIGURATION mode

io-aggregator auto-lag enable

Link Aggregation

125