Communication tool exportable results – Banner PresencePLUS P4 Series User Manual
Page 125
Description
Values
Option Name
The delimiter is used to separate
the individual pieces of data being
,
: < Colon>
Delimiter
sent. The delimiter will follow every
;
individual segment of data,
including start string and end
string.
\r\n
then line feed
\n\r
carriage return
\r
\n
This option is a mechanism for
adding characters before a string
of data.
User-defined ASCII characters
(limit of 75 characters)
Start String
Note: ASCII Hex characters
are allowed. Special symbols
such as \r, \n, and \t will cause
a carriage return, new line,
and tab to be output
repsectively.
This option is a mechanism for
adding characters after a string of
data.
User-defined ASCII characters
(limit of 75 characters)
End String
Note: ASCII Hex characters
are allowed. Special symbols
such as \r, \n, and \t will cause
a carriage return, new line,
and tab to be output
repsectively.
Check this box to add a label to
the data before the data itself.
Parameter labels
Enable Labels
Example: Dark Count = 3, where
"Dark Count=" is the label.
4. Set conditions for conditionally exporting the selected data (in the Output Filter field).
• Select Pass to export the selected information on a passing Test tool.
• Select Fail to export the selected information on a failing Test tool.
Communication Tool Exportable Results
The Communication tool sends out the data in the same sequence that the tools appear in the inspection, and
the result of transmitting this data will increase the inspection time.
The following shows the data sent out for each Communication tool.
125
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 000000
PresencePLUS Software Tools
7/2009