3.2 Typical Setup and Startup Sequence
The following subsections proceed through a typical Sensor setup and startup sequence
1. Connect and power up the hardware.
2. Start up the software.
3. Set up hardware parameters.
4. Build and run an inspection.
3.3 Startup and Troubleshooting
The following explains how to verify connections and start the PresencePLUS software.
1. Verify cable connections.
• The sensor is connected to a PC with an Ethernet crossover cable ofr a serial cable.
• The monitor, if used, is connected to the sensor's video port.
2. Thread the lens onto the sensor.
3. Verify electrical connections.
• +V is connected to Pin 12, brown were, 10-30V dc (24V dc ± 10% if a light is powered by the
sensor).
• -V is connected to Pin 11, blue wire (dc common).
• The trigger device is connected to Pin 4 (pink wire, Trigger In).
• Any additional connections are made as required.
4. Verify power. Ensure that the sensor is powered by 10-30V dc (24V dc ± 10% if a light is powered
by the sensor).
5. Verify PC configuration.
• Ethernet connection: IP address of PC is 192.168.0.2.
• Serial connection: A dial-up network has been established, and the network is a point-to-point
protocol (PPP).
6. Power up the hardware and verify that the Error LED turns off.