Application support, Scripting support – Rockwell Automation 2711PC-xxxx PanelView Plus 6 Compact Terminals User Manual User Manual
Page 74

74
Rockwell Automation Publication 2711PC-UM002B-EN-P - April 2014
Chapter 4
Windows CE Operating System
• VNC server and client viewer
The platform distributes two VNC client viewers:
– Vncviewer.exe in the \Windows folder on the terminal can be deployed
to a personal computer for connecting, viewing, and controlling the
Windows CE terminal (PanelView Plus 6 Compact).
– Another viewer is available on the terminal to establish a VNC
connection between two PanelView Plus 6 Compact terminals. To
access this VNC client, choose Start>Programs>VNC Viewer.
Application Support
The Windows CE 6.0 operating system provides the following application
support in both the OS and the Software Development Kit (SDK):
• .Net Compact Framework, version 3.5 or later
• C++ libraries and runtimes
• Component services DCOM/COM/OLE
• Message queueing MSMQ
• MSXML, version 3.0 or later
• MFC for devices, version 9.0 or later
• ATL
• ActiveSync
• CAB file installer/uninstaller
• Toolhelp API
• Error reporting (generator, transfer driver, control panel)
Scripting Support
The Windows CE 6.0 operating system supports these scripting features:
• Batch/command (BAT and CMD files)
• JScript
• VBScript
• CSScript
TIP
The Windows Explorer shell supports right-click functionality. A touch screen
press for one second or longer produces a right-click.