Install the ac power supply module – Rockwell Automation 2711PC-xxxx PanelView Plus 6 Compact Terminals User Manual User Manual
Page 119

Rockwell Automation Publication 2711PC-UM002B-EN-P - April 2014
119
Install and Replace Components
Chapter 5
5. Carefully lift the logic module away from the terminal and turn over to
expose the circuit board.
6. Locate the battery on the circuit board.
7. Remove the battery by lifting up the side of the battery.
The battery can be removed up to 15 seconds without losing clock and
calendar data.
8. Insert the new battery.
9. Reattach the logic module by aligning the two connectors on the bottom
of the logic module with the connectors on the back of the display module.
10. Push down on the logic module until it is firmly seated.
11. Tighten the four captive screws that secure the logic module to a torque
of 0.58 N•m (5…7 lb•in).
12. If necessary, reattach the communication module and torque the four
screws to 0.58 N•m (5…7 lb•in).
Install the AC Power Supply
Module
The AC power supply module, catalog number 2711P-6RSA, attaches to the
back of a DC-powered terminal to convert the terminal from DC to AC power.
Table 36 - AC Power Supply Ratings
You can install the AC module with the terminal mounted in the panel. No
special tools are needed.
Input Voltage
Power Consumption
100…240V AC (50…60 Hz)
35VA max