Rockwell Automation 1760-xxxx Pico Controller User Manual User Manual
Page 95
Publication 1760-UM001D-EN-P - September 2005
Draw a Circuit Diagram with Pico 4-35
Parameters for Counters
The parameter display for counters is used to change the counter
setpoint value and to enable or disable parameter access.
The symbol ‘
{
‘ before DIR, CNT and RES indicates whether the coil
function is programmed in the circuit diagram.
The actual value is only displayed in Run mode. The parameter
display can then be called via the power flow display or via the
PARAMETER option from the main menu.
The coil symbol is not displayed if you select the parameter display
via the PARAMETER menu option.
The counter relay counts between 0 and 32000.
When the Pico is in Run mode and the value of 32000 is reached, this
value is retained until the count direction is changed. If the value of
C2
Counter function relay number 2
N
• Mode N: up/down counter
• Mode H: high-speed up/down counter
• Mode F: frequency counter
+
• + appears in the Parameter menu
• - does not appear in the Parameter
menu.
S
Setpoint, constant from 00000 to 32000
Parameter
Coil Function
Meaning
DIR
DC1 to DC16
Counting direction
Coil not triggered: count up
Coil triggered: count down
CNT
CC1 to CC16
Counting pulse
RES
RC1 to RC16
Reset, coil triggered: actual value reset to
00000
Parameters Displayed via the PARAMETER Menu Option
+
Access enabled
-
Access disabled
C2 N +
00.000
S