Draw a Circuit Diagram with Pico 4-43
Compatibility between Pico Series A Controllers and Pico Series B Controllers
Parameters for Time Switch
A time switch has four sets of parameters, one for each channel (A, B,
C and D). These are used to set the day of the week and the turn-on
and turn-off times for the desired channels and to enable or disable
parameter access. Changing the switching times is described in
Chapter 7.
You can only change the ’+’/’–’ setting for displaying the parameters
via the PARAMETER menu option when you are editing the circuit
diagram.
The current time only appears in the parameter display in Run mode.
Call up the parameter display in Run mode via the power flow display
or via PARAMETER in the main menu.
Switch-On and Switch-Off Times
Ö1
7-day time switch function relay 1.
A, B, C, D
Time switch channels
+
• + Appears in the Parameter menu.
• - Does not appear in the Parameter menu.
D
Day setting, from -- to --.
ON
On time.
OFF
Off time.
Parameter
Meaning
Valid Setpoint Times
Day of the week
Monday to Sunday
MO, TU, WE, TH, FR, SA, SU
On time
Hours: minutes:
No time set: “--:--”
00:00 to 23:59, --:--
Off time
Hours: minutes:
No time set: “--:--”
00:00 to 23:59, --:--
D AA-BB