Text display, Text display -50 – Rockwell Automation 1760-xxxx Pico Controller User Manual User Manual
Page 110
Publication 1760-UM001D-EN-P - September 2005
4-50 Draw a Circuit Diagram with Pico
2. Press Ok to switch to the parameter display.
The parameter set for the first comparator is displayed.
3. Use the left and right arrows to move the cursor to the field
greater than or equal to. Use the up and down arrows to select
one of the comparator relays.
4. Press Ok to finish or enter another setpoint value. Press Esc to
return to the circuit diagram display.
Text Display
Series B Pico controllers allow you to display sixteen user-defined text
displays which can be edited in PicoSoft v.6.1 and higher. These texts
can be triggered by the actual values of function relays such as timing
relays, counters, operating hours counters, analog value comparators,
date, time or scaled analog values. The setpoints of timing relays,
counters, operating hours counters and analog value comparators can
be modified when the text is displayed. The text displays are saved in
the PicoSoft file or on the 1760-MM2B memory module.
If you need to load an existing 1760-18xxx, Series A circuit diagram,
the available text display functions are retained. The text display in
Series B controllers operates in the same way as in a Series A
controller.
A1 GE
I1 I7
F1 +0
I2 I8
F2 +0
OS +0
HY +0
A1 LE
I1 I7
F1 +0
I2 I8
F2 +0
OS +0
HY +0
A1 GE
I1 I7
F1 +0
I2 0.0
F2 +0
OS +0
HY +0
A1 GE
I1 I8
F1 +0
I2 0.0
F2 +0
OS +0
HY +0
A1 LE
I1 I7
F1 +0
I2 0.0
F2 +0
OS +0
HY +0
A1 LE
I1 I8
F1 +0
I2 0.0
F2 +0
OS +0
HY +0
I7 is greater than or equal
to I8
I7 is greater than or equal
to Setpoint
I7 is less than or equal to
Setpoint
I7 is less than or equal to
I8
I8 is greater than or equal
to Setpoint
I8 is less than or equal to
Setpoint