Chapter – Rockwell Automation 1203-GK5 DeviceNet Communications Module FRN 1.xxx-3.xxx User Manual
Page 21

Chapter
2
Configuring the 1203-GK5 Module or
1336-GM5 Board
Chapter Objectives
Chapter 2 provides instructions and information that you need to
configure the 1203-GK5 module or 1336-GM5 board. In this chapter,
you will read about the following:
•
Factory-default settings.
•
Configuring the adapter.
Factory-Default Settings
The 1203-GK5 and 1336-GM5 are shipped with these settings:
•
16-bit logic command/status enabled for polling.
•
16-bit reference/feedback enabled for polling.
•
If the scanner is put into program mode or the network fails, the
SCANport product is faulted by the module.
•
A node address of 63.
•
DeviceNet data rate of 125K.
Locating the DIP Switches
To configure the 1203-GK5 module or 1336-GM5 board, you must
set their DIP switches. On the 1203-GK5 module, DIP switches are
found in the following location.
Figure 2.1
Switches on the 1203-GK5 Module
AB0939
Bottom View
SW2.1 – SW2.6 = Node Address Selection
SW2.7 – SW2.8 = Data Rate Selection
SW1.1 = Datalink A
SW1.2 = Datalink B
SW1.3 = Datalink C
SW1.4 = Datalink D
SW1.5 = Not Used
SW1.6 = Zero Data / Hold Last State
SW1.7 = Fault on Comm Loss
SW1.8 = Fault On Pgm / Idle