Configuration assembly data formats (continued) – Rockwell Automation 160 DEVICENET (DN1) MODULE FRN 1-2.XX User Manual
Page 89
![background image](/manuals/577946/89/background.png)
Publication 0160-5.5 - September 1997
B-28
DeviceNet Information
Configuration Assembly Data
Formats (Continued)
Instance 191 Data Format (Fixed Configuration Assembly – All Preset Speed Models)
Config Num.
Parameter
Number
Description
Size
Config Num.
Parameter
Number
Description
Size
1
30
Accel Time 1
2
18
47
Output Configuration
1
2
31
Decel Time 1
2
19
48
Output Threshold
2
3
32
Minimum Frequency
1
20
49
PWM frequency
1
4
33
Maximum Frequency
2
21
50
Restart Tries
1
5
34
Stop Mode Select
1
22
51
Restart Time
2
6
35
Base Frequency
2
23
61
Preset Frequency 0
2
7
36
Base Voltage
2
24
62
Preset Frequency 1
2
8
37
Maximum Voltage
2
25
63
Preset Frequency 2
2
9
38
Boost Select
1
26
64
Preset Frequency 3
2
10
39
Skip Frequency
2
27
65
Preset Frequency 4
2
11
40
Skip Frequency Band
1
28
66
Preset Frequency 5
2
12
41
Motor Overload Select
1
29
67
Preset Frequency 6
2
13
42
Motor Overload Current
2
30
68
Preset Frequency 7
2
14
43
Current Limit
1
31
69
Accel Time 2
2
15
44
DC Hold Time
1
32
70
Decel Time 2
2
16
45
DC Hold Voltage
1
17
46
Input Mode
1
!
!
Instance 192 Data Format (Fixed Configuration Assembly – All Signal Follower Models)
Config Num.
Parameter
Number
Description
Size
Config Num.
Parameter
Number
Description
Size
1
30
Accel Time 1
2
13
42
Motor Overload Current
2
2
31
Decel Time 1
2
14
43
Current Limit
1
3
32
Minimum Frequency
1
15
44
DC Hold Time
1
4
33
Maximum Frequency
2
16
45
DC Hold Voltage
1
5
34
Stop Mode Select
1
17
46
Input Mode
1
6
35
Base Frequency
2
18
47
Output Configuration
1
7
36
Base Voltage
2
19
48
Output Threshold
2
8
37
Maximum Voltage
2
20
49
PWM frequency
1
9
38
Boost Select
1
21
50
Restart Tries
1
10
39
Skip Frequency
2
22
51
Restart Time
2
11
40
Skip Frequency Band
1
23
53
S-Curve
1
12
41
Motor Overload Select
1
!
!
!
ATTENTION: Changing this parameter value may cause unpredictable network conditions, resulting in equipment damage, personal injury, or death.