For detailed, Ng length 2. see, Set length 2 – Wasp Barcode WLS9600 Product Reference Guide User Manual
Page 253

Symbologies
Product Reference Guide
243
Set Length 2
This feature allows you to set one of the barcode lengths for the specified symbology. Length 2
is the maximum label length if in
Variable Length
Mode, or the second fixed length if in
Fixed
Length
Mode. See the page for the specific symbology for parameters.
The length that can be set varies depending on the symbology. A setting of 0 specifies to ignore
this length (only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad
the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,
etc.
2. Go to the Set Length page for your selected symbology and scan the ENTER/EXIT PRO-
GRAMMING MODE barcode to enter Programming Mode.
3. Scan the barcode to SELECT LENGTH 2 SETTING for your selected symbology.
4. Scan the appropriate two digits from the keypad in
that represent
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
If you make a mistake, before the last character scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.