4hydraulics, 1reservoir, Checking oil level – MacDon FD75 OM User Manual
Page 288: Hydraulics, Reservoir, 4 hydraulics, 1 reservoir
![background image](/manuals/570554/288/background.png)
6.4
Hydraulics
The CA25 Combine Adapter’s hydraulic system drives the adapter feed draper, the header drapers, and knife
drive(s). Reel hydraulics are provided by the combine.
6.4.1
Reservoir
The adapter frame is used as a reservoir.
Refer to
6.2.2 Recommended Fluids and Lubricants, page 244
for oil requirements.
Checking Oil Level
Check oil level every 25 hours at lower (A) and upper (B)
sights with cutterbar just touching ground.
Check level
when oil is cold, and with center-link retracted.
• Maximum - Hilly Terrain (C): Maintain level so lower
sight (A) is full, and upper sight (B) is up to one-half filled.
• Nominal - Normal Terrain (D): Maintain level so lower
sight (A) is full, and upper sight (B) is empty.
• Minimum - Level Ground (E): For slopes of 6 degrees
or less, oil level may be kept slightly lower if desired.
Maintain level so lower sight (A) is one-half filled or
slightly higher.
NOTE:
When ambient temperatures are above 95°F
(35°C), it may be necessary to lower oil level
slightly to prevent overflow at breather under
operating temperatures.
Figure 6.36: Oil Level Sights
169894
274
Revision A