Appendix, Communication object list – Lenze 931E/K Small Drives Control User Manual
Page 167

Appendix
Communication object list
l
167
SW−HB 13.0002−EN 4.1
Scaling
Meaning
Name
No.
0087
ioh_aout_range
Value range of analog monitor (maximum) for
both channels
Base unit voltage
0088
ioh_aout_resolution_volt
Resolution of analog monitor, voltage
indication for one bit referred to the value
range
Base unit voltage
0089
ioh_dout2_1_func
Determines the functionality assignments for
the digital outputs.
None
008A
ioh_aout0_ko_nr
Analog monitor 0: Communication object
number of value to be output.
Communication object number of
value to be output.
008B
ioh_aout0_scale
Analog monitor 0: Scaling
Base unit gain
008C
ioh_aout0_offset
Offset voltage for analog monitor
Base unit voltage
008D
ioh_aout1_ko_nr
Analog monitor 1: Communication object
number of value to be output.
Communication object number of
value to be output.
008E
ioh_aout1_scale
Analog monitor 1: Scaling
Base unit gain
008F
ioh_aout1_offset
Offset voltage for analog monitor
Base unit voltage
0090
ioh_ain0_offs
AIN0 offset
Base unit voltage
0091
ioh_ain1_offs
AIN1 offset
Base unit voltage
0092
ioh_ain0_safezero
Safe zero
Base unit voltage
0093
ioh_ain1_safezero
Safe zero
Base unit voltage
0094
ioh_control
Configuration of analog monitor &
temperature sensor
None
0095
ioh_pins_used
Optionally, the values for DIN0.. DIN3 can be
parameterised as AIN0, #AIN0, AIN1, #AIN1
None
00A0
eeval_enc_phi
Rotor position without angle encoder offset
Base unit degrees
00A1
enc_config
Encoder configuration word
None
00A2
emu_ctrl
Operating mode selection
None
00A3
eeval_enc_phi_offs
Offset angle of angle encoder − one rev.
Base unit degrees
00A4
eeval_x2b_line_cnt
Increments of analog incremental encoder
Increments = 4 x number of
increments
00A5
emu_enc_line_cnt
Output increments of encoder emulation
Increments = 4 x number of
increments (32 ..1024)
00A6
emu_enc_offset
Offset between setpoint angle and output
angle of encoder emulation
Base unit degrees
00A7
eeval_motid_w_status
Status of Motid_w
None
00A8
enc_sync_num
Synchronisation gearbox factor (numerator)
None
00A9
enc_sync_div
Synchronisation gearbox factor (denominator) None
00AA
enc_encoder_status
Angle encoder status
None
00AB
enc_hiperface_line_cnt
Increments of SINCOS encoder
None
00AC
eeval_enc_phi_offs_2
Offset angle of 2nd track, e.g. Hall encoder for
incremental encoder
Base unit degrees
00C0
currc_i_q_act
Actual active current in rotor coordinates
Base unit current
00C1
currc_i_d_act
Actual reactive current in rotor coordinates
Base unit current
00C2
currc_i_q_ref
Active current setpoint in rotor coordinates
Base unit current
00C3
currc_i_d_ref
Reactive current setpoint in rotor coordinates
Base unit current
00C4
currc_iit_pwr_level
Current status of i2t integrator for power stage Base unit percent
00C5
currc_iit_mot_level
Current status of i2t integrator for motor
Base unit percent
00C6
currc_i_lim_act
Current torque limitation
Limited to 0 − i_max
Base unit current
00C7
currc_i_ref_rs232
Setpoint torque − RS232
Base unit current
00C8
currc_i_ref_can
Setpoint torque − CAN
Base unit current
00C9
currc_i_ref_ftd
Setpoint torque − FTD
Base unit current