beautypg.com

3 external relay module er8, External relay module er8, 10 extra codes and accessories – JUMO 706030 LOGOPRINT 500 Printing Recorder Operating Manual User Manual

Page 93

background image

93

10 Extra codes and accessories

10.3 External relay module ER8

The external relay module ER8 adds 8 switching outputs to the recorder.

The sequence of the relays 1 — 8 is permanently assigned to the limit compa-
rators 1 — 8 (limit state). The corresponding limit state is only transferred to
the relay if the relay has been activated (Configuration level 3

Î

Relay output

Î

Status = ON).

v Section 3.1 “Limit monitoring by limit comparators”
v Section 3.5.4

“Limit comparator texts, external text, binary-linked external text”

v Section 4.2 “Table of the configuration parameters”

H

The external realy module ER8 can only be operated when the
Extra Code has been installed in the recorder.

A

When the setup connector is plugged into the recorder, all relays
are de-energised.