Page 55: 4 configuration table

55
4 Configuration table
4.2 Table of the configuration parameters
All the parameters for the instrument are presented in the following table. The
parameters are explained in the order in which they appear in the recorder.
The first column of the table shows the path through the levels to the particular
parameter.
The settings or selections which are available for the parameter are shown in
the second column.
The third column contains a description of the parameter or the selection op-
tions, if the selection or the function of the parameter are not obvious.
4.2.1
Operating level (S-level)
H
The “X” symbol stands for a number which is to be selected (e.g.
channel number 1 — 3 or 1 — 6). This number is shown in the dis-
play of the printing recorder for all the sub-parameters.
To preserve a clear layout, the “X” is only shown for the first sub-
parameter in the table.
Parameter
Value/selection
Description
Chart speed
Operating level
➔ Chart speed
Chart speed:
0, 5, 10, 20, 60, 120, 240,
300, 360, 600, 720mm/h
Setting the chart paper
speed
Print test
Operating level
➔ Print test
Print test:
OFF, ON
Start print test
The print test can be used
to test the functioning of
the printing system
Service print
Operating level
➔ Service print
Service print:
NO, YES
Start service print
The service print provides
information about the soft-
ware version, no. of mains
power supply interruptions,
total no. of operational
hours of the recorder, the
count states of the event
counters 1 and 2, and the
minimum and maximum
ambient temperatures.
Version number
Operating level
➔ Version number
Version:
105.02.01
Displays the number of the
software version