Command:

C

Parameter:

None

Description:

Zeros only the thickness.

_________________________________________________________________________

Command:

D

Parameter:

None

Description:

Zeros only the timer.

_________________________________________________________________________

Command:

E

Parameter:

=[0.500 .. 99.99] | [?]

Description:

Sets the density parameter of the currently selected film. If a "?" is sent as a
parameter, the current density value is returned. The units are gm/cc.

_________________________________________________________________________

Command:

F

Parameter:

=[0.100 .. 9.999] | [?]

Description:

Sets the material Z-Factor of the currently selected film. If a "?" is the parameter, the
current Z-Factor is returned.

_________________________________________________________________________

Command:

G

Parameter:

=[0 .. 9999000] | [?]

Description:

Sets the end thickness of the currently selected film. While any resolution number
can be programmed (up to 7 digits), the number that is accepted by the
STM-100 / MF will be within the display range. This is limited to a total of 4 digits.
The units are Angstroms.

_________________________________________________________________________

Command:

H

Parameter:

=[0 .. 9999000] | [?]

Description:

Set the setpoint relay thickness limit of the currently selected film. See the
description for the G command.

_________________________________________________________________________

Command:

I

Parameter:

=[00:00 .. 99:59] | [?]

Description:

Set the setpoint timer relay of the currently selected film. The format is
"Minutes:Seconds". A "?" will return the current value.

_________________________________________________________________________

Command:

J

Parameter:

=[10.0 .. 399] | [?]

Description:

Set the tooling factor parameter of the currently selected film. A "?" will return the
current value. The units are in percent.