RS-232 SERIAL COMMUNICATIONS INTERFACE
This Connection provides a serial transmission data communications link to
the STM-100 / MF. Four standard baud can be selected: 300, 1200, 2400, and
9600. They are selected via the rear panel configuration dip switches. (See
Section 2.5) The serial interface communications protocol is also selectable on
these switches. The choices are SEMI STANDARD SECS-II, or Sycon format.
The electrical specifications correspond to the RS-232 standard.
CONNECTOR TYPE
9 PIN "D" FEMALE
CONNECTOR MATE
AMPHENOL 117-DA9P OR EQUIVALENT
STM-100 / MF FUNCTION
PIN NUMBER
RECEIVED DATA ............................ 2
TRANSMITTED DATA ..................... 3
CLEAR TO SEND ............................ 8
DATA TERMINAL READY ............... 4
SIGNAL GROUND ........................... 5
CABLE SHIELD ............................... 9
STM-100 / MF
9 PIN MALE
SHIELD
9 PIN FEMALE
IBM-AT
2 RxD
3 TxD
9
5 GND
DSR 6
RxD 2
TxD 3
CTS 8
DTR 4
GND 5
STM - 100 / MF
9 PIN MALE
SHIELD
IBM - PC,XT
25 PIN FEMALE
2 RxD
3 TxD
9
5 GND
TxD 2
RxD 3
CTS 5
DSR 6
GND 7
DTR 20
Figure 3.6: Cable Connections From STM to MSDos Computers.
SECTION 3.7
RS-232 Connections
RS-232 CONNECTOR
DEFINITIONS
Page 3 - 7
INSTALLATION