5

Install Rack Options

37

Connect CAT5e Wiring

Step 1:

Pull your CAT5e building wire through the conduit access previously prepared.

Step 2:

The punch down connector provides insulation displacement therefore stripping

of wire is not required. Reference the connector label for the color code for Cat5e
wire using the 568B standard.

Step 3:

Install the protective covers over the wire terminals.

Step 4:

Install the punch down connector on the patch panel.

Step 5:

Connect Ethernet patch cables.
a: Connect a patch cable from the left I/O to the first RJ-45 input on the Ethernet

Switch panel.

b: Connect a patch cable from the punch down connector to an RJ-45 input on

the switch panel. Repeat for each building service connection (up to four).

Step 6:

Install the Ethernet Switch Module into the enclosure and secure it in place using

the captured screws provided.

N o t e :

All Ethernet terminations must follow IEEE 802.3 and be terminated to the T568B

standard.

N o t e :

Use a 110 punch down tool to complete the wire termination.

As needed, press here gently

with screwdriver to release

connector from panel.