Install the Ethernet Switch Module

The ERn Ethernet Switch Module installs in the bottom option module tray of the ERn

enclsoure, replacing the blank module that ships with the rack from the factory. The bottom

option slot is the only position for the Ethernet Switch Module.

An ERn Ethernet Switch (ERn-NET) provides five ports of Power over Ethernet (PoE). The

kit includes , a Switch module patch panel, Ethernet Switch panel, and five patch cables.

The Ethernet patch panel includes four punch down terminal blocks that accept CAT5e

wire. Building wire enters the ERn enclosure and terminates to this patch panel. For each

Ethernet data run, an Ethernet patch cable is provided to connect between the Ethernet

patch panel and the Ethernet Switch panel.

Step 1:

Install the Ethernet patch panel to the mounting studs on the rear panel of the

ERn enclosure using the hardware provided.

Step 2:

Install the Ethernet Switch panel to the mounting studs on the bottom panel of

the ERn enclosure using the hardware provided. Be sure to install the panel with

the card edge receptacle facing the front of the ERn enclosure.

N o t e :

The ERn Ethernet Switch module (ERn-NET) is not supported in an ERn4

enclosure at 230 VAC, nor is it compatible with a rack mounted ERn enclosure.

N o t e :

The ERn-NET option is intended for use only in wall mount ERn enclosures and

is not compatible with rack mounted enclosures.